Features:
1. 480W 18chs Output Power Supply Box
2. Output voltage & current: DC12V 40A
3. Input voltage range: 85~264VAC
4. Built in EMI filter with tiny ripple
5. 100% full load burn-in test
6. Air Cooling
7. Protection: Short circuit/ Overload/ Over voltage/ Over temperature
8. Built-in constant current limiting circuit (C.C.+C.V.mode);
Specification:
Model
|
CP1209-40A-18
|
Output
|
DC output Voltage
|
12V±1%
|
Output Current Range
|
0-40A
|
Wave and Noise
|
120mVp-p
|
DC output Power
|
480W
|
Efficiency
|
85%
|
DC Voltage Adjustable Scope
|
(at full load)≦0.5%
|
Input
|
Voltage Range
|
85~264VAC 47-63Hz
|
Input Current
|
4.6A/115V, 2.3A/230V
|
Leakage Current
|
<1mA/ 240VAC
|
Inrush Current
|
Cold start 20A/120VAC, 40A/230VAC
|
Protection
|
Over-load
|
105%~135%, Protection type: Constant current limiting,
recovers automatically after fault condition is removed
|
Over-voltage
|
105%---150% Rated Voltage, Protection type: Shut off
|
High-temperature
|
RTH3>=65°C FAN ON<=55°C FAN OFF>=80°C Cut off output(5~15V)
|
Environment
|
Working temperature and humidity
|
-10°C~+50°C, 20~90%RH
|
Store temperature and humidity
|
-20°C~+85°C, 10~95%RH
|
Temperature coefficient
|
±0.03%°C(0~50°C)
|
Vibration
|
10~500Hz,2G 10min./1cycle,Period for 60min,EACH AXES
|
Safety
|
Withstand voltage
|
I/P-O/P: 1.5KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC
|
Isolation resistance
|
I/P-O/P,I/P-FG,O/P-FG: 100M Ohms/500VDC
|
Standard
|
CE EMC Standard
|
EN55015:2013+A1:2015, EN61547:2009, EN61000-3-2:2014, EN61000-3-33:2013
|
CE LVD Standard
|
EN61347-2-13:2014+A1:2017, EB61347-1:2015
|
ROHS Standard
|
IEC 62321: 2013, EPA3050B:1996, EN1122:2001, EPA3052:1996, EPA3060A, etc.
|
Other
|
Dimension
|
215*315*63mm (L*W*H)
|
Weight
|
2.3kg
|
Notes
|
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. I/P-O/P: Input and output interval, I/P-FG: Input and enclosure, O/P-FG: Output and enclosure
|
|